The radon rough-in is the only thing your crew installs that is designed to do nothing.
That is not a criticism of it. A rough-in is a provision, not a system, and the code says so in the title of the article that requires it. But it has a consequence that catches builders out: the rough-in is finished, inspected and buried while the one measurement that decides whether it was ever needed cannot be taken for months. By then you are off the site, and the cost of having put the stub in the wrong place has moved onto someone else’s ledger.
Below is what the Alberta code obliges you to build, which Part of the code governs which half of the job, and the Calgary measurements that should change how your site team treats it.
Where the rough-in requirement comes from, and what it consists of
Alberta has required a radon rough-in in new housing since the Alberta Building Code 2014 came into force on 1 November 2015. It applies to new homes with a foundation in contact with the ground, and it obliges the builder to provide a rough-in for a subfloor depressurization system rather than a working mitigation system.
In the model code the work sits in a short run of articles that have survived several editions intact. The Canadian National Radon Proficiency Program’s interpretive guide still lists the same numbering for the current model code: 9.13.4.1 Soil Gas Control, 9.13.4.2 Protection from Soil Gas Ingress, and 9.13.4.3 Providing for the Rough-in for a Subfloor Depressurization System, with a note at A-9.13.4.3, plus 9.14.4 Granular Drainage Layer and 9.14.5.2 Sump Pits nearby. The article numbers you cited on a drawing three editions ago still point at the same subject.
In physical terms the rough-in is four pieces of work, and no one trade owns all four:
- a layer of clean aggregate under the floor slab, so that soil gas can collect and move toward one point
- a sealed membrane beneath the slab
- a capped pipe stub running from under the slab up into the house
- provision so that a fan can be added later without opening the slab
Health Canada describes the same assembly in fewer parts: the sealing of soil gas entry points, granular material below the slab, and a capped stub rising from the floor. The secondary guides differ on whether the electrical provision is obligation or good practice, which is a reason to take the element list off the drawings rather than off a web page, and to confirm it with your authority having jurisdiction before the gravel is spread.
The split that decides who designs it: Part 9 provides, Part 6 engineers
Two Parts of the code touch radon, and they ask different things of different people.
Part 9 is where the rough-in lives, and it is prescriptive in the ordinary way: a builder installs it, an inspector looks at it, it is done. Part 6, which governs the building’s environmental systems, does not prescribe a mitigation system at all. When soil gas mitigation is required under Part 6, it has to be designed, constructed and installed by a registered engineering professional, and the choice of system is left to that professional’s discretion. Alberta Municipal Affairs has had to clarify this split publicly, which tells you how often it gets read the wrong way.
The practical reading for a general contractor is this. On a Part 9 house, you owe a provision. On anything that falls to Part 6, you owe a professional, and you owe them early enough that their design reaches your under-slab sequence rather than arriving after it. The expensive version of this mistake is not a code violation. It is a correctly installed rough-in that an engineer later tells you is in the wrong place for the system the building needs.
Alberta’s stated approach is that the rough-in is to be augmented by testing and further design under Part 6 and good engineering practice. The provision is the floor, not the answer.
The Calgary numbers that make this more than a paperwork item
The reason to care about a capped pipe is that in this city the gas behind it is measurably common. A survey of southern Alberta households published in CMAJ Open tested 2,382 homes, 2,018 of them in Calgary and 364 in surrounding townships:
| Measure | Result |
| Homes tested | 2,382 (2,018 Calgary, 364 surrounding townships) |
| Average indoor radon level | 126 Bq/m3 |
| Homes at or above 100 Bq/m3 | 1,135 (47.6%) |
| Homes at or above 200 Bq/m3 | 295 (12.4%) |
| Canada’s radon guideline | 200 Bq/m3 |
One home in eight in that sample sat at or above the Canadian guideline of 200 Bq/m3, and close to half sat at or above 100 Bq/m3. The study also found that geographic location within the region was not an effective predictor of radon levels. There is no map of this city that lets you decide a lot is fine.
Two findings in the same study speak directly to where concrete sits in the problem. Basements measured significantly higher than ground or first floors, and utility spaces measured higher than living spaces. Both are rooms with a slab under them and services coming through it.
Newer homes measured higher, and builders should read that twice
Here is the finding worth carrying out of this article. In the same survey, homes built in 1992 or later measured 31.5% higher on average than older homes: a mean of 142 Bq/m3 against 108 Bq/m3, with medians of 103 and 85 Bq/m3. The University of Calgary’s Evict Radon team reports the same figure from the same work.
Be careful what you take from it. The study’s dividing line is 1992, not the 2015 rough-in date, so this is not a verdict on code-era construction and not evidence that the requirement failed. The useful reading is narrower: the newer, tighter, better sealed house is not the safer house on this measure, and the intuition that modern construction has already solved soil gas does not survive contact with the data.
That bears directly on the envelope decisions being made next to your concrete, and we work through how airtightness, mechanical balance and slab penetrations interact at the foundation in our guide to Net Zero and suite-ready foundations in Calgary.
Where the rough-in lands in your sequence
The rough-in is cheap in the right week and a demolition job in the wrong one. Four points in a normal foundation sequence decide which you get.
| Stage | What has to be right |
|---|---|
| Granular placement | Clean aggregate placed as a continuous gas-permeable layer, not as scattered fill |
| Membrane | Membrane laid and sealed as a plane, with laps and penetrations closed |
| Stub set and capped | Pipe located where a fan run can reach it later, capped and protected through the pour |
| Pre-slab review | Layer, membrane, stub and penetrations checked together before any concrete arrives |
The item that gets missed is the third one, for an understandable reason: the pipe is set at a moment when nobody on site is thinking about a fan that may be installed in five years. Decide the route before the stub location, not after. Everything in that table is also an item on a wider pre-pour check, and our pre-backfill foundation checklist covers the rest of what should be confirmed while it is all still visible.
The dimensions belong on the drawings, not in a blog post
One honest limit. The code’s own numbers for this assembly, including pipe size and the thickness and gradation of the gas-permeable layer, sit inside the Alberta edition of the code, a purchased document whose tables we are not going to reproduce or paraphrase here. A paraphrased dimension is worth nothing to an inspector.
So the rough-in should arrive on your drawings as dimensioned detail, from the designer, before the layer goes in. If it arrives as the word “radon” on a general note, send it back. After 38 years pouring concrete in this city, we have sat through enough under-slab reviews to know that an undimensioned note is a decision the site is being asked to make on its own.
Sealing is the half of this you can get right without any of those numbers. Soil gas comes in at joints, service penetrations and the slab perimeter, and the detailing that closes those is ordinary concrete work done attentively. Our page on concrete joints covers how those are planned, and the discipline that keeps a slab’s joints tight keeps soil gas out of a utility room.
What the code does not require: a test
The gap at the centre of this subject is not in the installation. It is after it.
The rough-in is a provision for a system that may never be installed, and the only way to know whether the house needs that system is to measure it after it is built and occupied. Health Canada is direct about the consequence: a rough-in on its own can leave a high-radon home untested and unmitigated, and current best practice calls for more than the minimum provision. Alberta’s position is that the rough-in is augmented by testing, but the obligation to carry out that test does not land on the builder.
So the rough-in you install is a decision deferred, and you determine how cheap that deferred decision will be to act on. A stub in a reachable location with a known route and a dimensioned detail behind it costs a future owner a fan. A stub placed for the convenience of the gravel crew costs them a slab.
Slab-level moisture and gas questions tend to arrive together, and our guide to concrete slab moisture testing in Calgary covers the other half of what gets measured through a finished floor.
FAQ
Is a radon rough-in required in Alberta? Yes. New homes with a foundation in contact with the ground have required a rough-in for a subfloor depressurization system since the Alberta Building Code 2014 came into force on 1 November 2015.
Which code articles govern radon work? In the model code the subject sits at 9.13.4.1 Soil Gas Control, 9.13.4.2 Protection from Soil Gas Ingress and 9.13.4.3 Providing for the Rough-in for a Subfloor Depressurization System, with related requirements at 9.14.4 and 9.14.5.2.
Does a rough-in mean the house is protected from radon? No. A rough-in is a provision that makes a later system easier to install. Only a measurement taken in the finished, occupied house shows whether a system is needed.
Who designs a mitigation system when one is required? Where Part 6 applies, soil gas mitigation has to be designed, constructed and installed by a registered engineering professional, and the choice of system is at that professional’s discretion.
How common are high radon levels in Calgary? In a survey of 2,382 southern Alberta homes, 12.4% were at or above the Canadian guideline of 200 Bq/m3 and 47.6% were at or above 100 Bq/m3, with an average of 126 Bq/m3.
Are newer homes safer? Not on this measure. Homes built in 1992 or later averaged 31.5% higher radon levels than older homes in that survey, at 142 Bq/m3 against 108 Bq/m3.
Does the lot location tell me whether radon will be a problem? No. The study found that geographic location within the region was not an effective predictor of radon levels.
Talk to us before the gravel goes in
The radon rough-in is decided in the same week as the granular layer, the membrane and the service penetrations, which means it is decided before most project teams have thought about it once. That is the week to get it right, because each element is buried by the next.
If the radon detail on your foundation drawings is still a general note, bring it to us while the under-slab sequence is open. Our concrete foundations crews set these provisions as part of the under-slab package, and the time to locate a stub is before anyone has spread aggregate over the place it was supposed to go.
Sources
- Health Canada, Radon action guide for municipalities, building codes, bylaws and provisions: https://www.canada.ca/en/health-canada/services/health-risks-safety/radiation/radon/action-guides/municipalities/building-codes-bylaws-provisions.html
- CMAJ Open, Comprehensive survey of household radon gas levels and risk factors in southern Alberta: https://www.cmajopen.ca/content/5/1/E255
- University of Calgary, Evict Radon fact sheet: https://ucalgary.ca/news/evict-radon-fact-sheet
- Canadian National Radon Proficiency Program, Radon Document Interpretive Guide: https://c-nrpp.ca/wp-content/uploads/2026/07/CNRPP-Bulletin-Radon-Document-Interpretive-Guide.pdf